各位師傅
我在PLC的訊息裡面得到以下消息
像這樣我怎麼知道要去哪裡做異常判斷呢?
做怎樣的處理?
Diagnostic buffer of module CPU 315-2 DP
Order No./ Description Component Version
6ES7 315-2AF03-0AB0 Hardware 1
- - - Firmware V 1.2.0
Rack: 0
Slot: 2
Event 1 of 10: Event ID 16# 4302
Mode transition from STARTUP to RUN
Startup information:
- Time for time stamp at the last backed up power on
- Single processor operation
Current/last startup type:
- Automatic warm restart after backed up power on
Permissibility of certain startup types:
- Manual warm restart permitted
- Automatic warm restart permitted
Last valid operation or setting of automatic startup type at power on:
- Automatic warm restart after backed up power on
Previous operating mode: STARTUP (warm restart)
Requested operating mode: RUN
Incoming event
09:16:13.960 AM 09/26/2013
Event 2 of 10: Event ID 16# 1382
Request for automatic warm restart
STOP due to: STOP caused by stop switch being activated
Startup information:
- Startup without modified system configuration
- No difference between setpoint and actual configuration
- Time for time stamp at the last backed up power on
- Single processor operation
Current/last startup type:
- Automatic warm restart after backed up power on
Permissibility of certain startup types:
- Manual warm restart permitted
- Automatic warm restart permitted
Last valid operation or setting of the automatic startup type at power on:
- Automatic warm restart after backed up power on
Requested OB: Startup OB (OB100)
Priority class: 27
Incoming event
09:16:13.956 AM 09/26/2013
Event 3 of 10: Event ID 16# 4301
Mode transition from STOP to STARTUP
STOP due to: STOP caused by stop switch being activated
Startup information:
- Time for time stamp at the last backed up power on
- Single processor operation
Current/last startup type:
- Automatic warm restart after backed up power on
Permissibility of certain startup types:
- Manual warm restart permitted
- Automatic warm restart permitted
Last valid operation or setting of the automatic startup type at power on:
- Automatic warm restart after backed up power on
Previous operating mode: STOP (internal)
Requested operating mode: STARTUP (warm restart)
Incoming event
09:16:13.712 AM 09/26/2013
Event 4 of 10: Event ID 16# 5371
Distributed I/Os: End of the synchronization with a DP master/IO controller on slot 2
Number of distributed stations: 6
Incoming event
09:16:13.235 AM 09/26/2013
Event 5 of 10: Event ID 16# 4300
Power on backed up
Previous operating mode: No voltage
Requested operating mode: STOP (own initialization)
Incoming event
09:16:07.211 AM 09/26/2013
Event 6 of 10: Event ID 16# 494E
Power failure
Previous operating mode: STOP (internal)
Requested operating mode: No voltage
External error, Incoming event
09:08:37.623 AM 09/26/2013
Event 7 of 10: Event ID 16# 4303
STOP caused by stop switch being activated
Previous operating mode: RUN
Requested operating mode: STOP (internal)
Incoming event
09:08:09.773 AM 09/26/2013
Event 8 of 10: Event ID 16# 38C4
Distributed I/Os: station return
Address of the affected DP slave: station number: 20
DP master system ID: 1
Log. base address of the DP slave: Input address: 1017
Log. base address of the DP master: 1023
Requested OB: Rack failure OB (OB86)
Priority class: 26
External error, Outgoing event
08:57:55.883 AM 09/26/2013
Event 9 of 10: Event ID 16# 2942
I/O access error, reading
P area, word access, Access address: 90
Requested OB: I/O access error OB (OB122)
Priority class: 1
External error, Incoming event
08:57:55.826 AM 09/26/2013
Event 10 of 10: Event ID 16# 2942
I/O access error, reading
P area, word access, Access address: 90
Requested OB: I/O access error OB (OB122)
Priority class: 1
External error, Incoming event
08:57:55.803 AM 09/26/2013